Have you ever stepped into a cold shower on a winter morning, waiting for hot water that never comes? For homeowners with a gas water heater, a cold shower can be a sign of a problem – either the gas supply has been shut off or the pilot light is out. Understanding how to safely and effectively relight your pilot light is an essential home maintenance skill.
At Valley Plumbing NW, we understand the frustration of a cold shower. As your trusted, locally-owned plumbing service provider, we specialize in residential plumbing solutions across Yamhill, Washington, Multnomah, and Marion counties.
Key Takeaways
- Discover the common causes of a cold shower due to a gas water heater issue.
- Learn how to safely relight your pilot light.
- Understand when a pilot light issue might indicate a more serious problem.
- Identify the steps to troubleshoot and fix your pilot light issue
Understanding Your Water Heater’s Pilot Light

Standard water heater unit showing pilot light access panel.
What Is a Pilot Light and Why It Matters
A pilot light is a continually burning flame that is responsible for igniting the burner of your gas-powered hot water heater. When the pilot light goes out, you won’t have any hot water in your home. This small flame plays a crucial role in your gas water heater’s operation, and when it goes out, the safety mechanisms prevent gas flow to the main burner, resulting in no heat transfer to your water.
Types of Water Heaters That Use Pilot Lights
Not all water heaters use pilot lights. Gas water heaters rely on pilot lights, while electric water heaters and most modern tankless systems use electronic ignition systems instead. The pilot light’s flame should appear blue and steady when functioning properly; a yellow or flickering flame can indicate problems with the gas mixture or ventilation.
Modern water heaters may feature either standing pilot lights, which burn continuously, or electronic ignition systems that only activate when heating is needed. The latter is more energy-efficient.
Safety First: Precautions Before You Begin

Important safety tips before relighting your pilot light.
Safety should always be your top priority when working with gas appliances like your water heater. We understand that dealing with gas systems can be intimidating, but by following the right safety protocols, you can minimize risks and ensure a safe repair process.
Gas Safety Essentials
When working with gas appliances, it’s crucial to be aware of the potential hazards. If you smell gas (often compared to the smell of rotten eggs), leave your home immediately and call your gas company from a safe location. Before starting any work on your water heater, ensure the area is well-ventilated and free from flammable materials. Familiarize yourself with your water heater’s gas shut-off valve location so you can quickly turn off the gas supply in case of an emergency.
Tools You’ll Need
To relight your pilot light safely, you’ll need a few basic tools: a long lighter or fireplace match, a flashlight to help you see the pilot assembly, and possibly a screwdriver if access panels need to be removed. Having these tools ready will make the process smoother and safer.
When to Call a Professional Instead
Some situations require professional help rather than DIY approaches. If you’ve made multiple unsuccessful attempts to relight the pilot, if you detect persistent gas odors, or if your water heater shows signs of damage or corrosion, it’s time to contact our team at (503) 405-8391 or online. Our team offers comprehensive services, including water heater installation and repairs for electric, gas, and tankless systems.
| Safety Precaution | Description |
|---|---|
| Ventilation | Ensure the area is well-ventilated to prevent gas accumulation. |
| Gas Shut-off | Familiarize yourself with the gas shut-off valve location. |
| Professional Help | Call a professional if you detect gas odors or see damage/corrosion. |
How to Relight Your Water Heater Pilot Light: Step-by-Step Guide

Step-by-step instructions to relight your water heater pilot light.
If your water heater’s pilot light has gone out, don’t worry, we’re here to guide you through the relighting process. Relighting the pilot light is a relatively simple process that requires some basic knowledge and precautions.
Step 1: Turn Off the Gas and Wait
Safety begins with turning off the gas control valve on your water heater. Wait 5-10 minutes to allow any accumulated gas to dissipate, reducing the risk of accidental ignition.
Step 2: Locate Your Pilot Light
Find the pilot light assembly, typically located underneath the gas valve or behind a small access panel on your water heater. You may need to remove a cover plate to access it.
Step 3: Set the Gas Valve to “Pilot” Position
Once you’ve located the pilot assembly, turn the gas control knob to the “PILOT” position. This allows a small amount of gas to flow to the pilot light area when you’re ready to light it.
Step 4: Light the Pilot
While holding down the reset button or pressing in the gas control knob, use a long lighter or match to ignite the pilot light. Continue holding the button/knob for about 30-60 seconds after the pilot lights.
Step 5: Restore Normal Operation
After the pilot stays lit, turn the gas control valve to the “ON” position, replace any access panels, and adjust the temperature setting to your desired level.
Throughout this process, pay attention to the pilot flame quality. It should be blue with perhaps a slight yellow tip, indicating proper combustion. Give your water heater time to heat up after relighting the pilot (it may take 30-60 minutes to produce hot water). Test your success by running hot water at a faucet after the appropriate heating time has passed
Brand-Specific Instructions for Common Water Heaters

Brand specific instructions for common water heaters.
Different manufacturers have designed their systems with specific safety features and operational procedures. It’s essential to review each brand’s model guide for the most accurate and up-to-date instructions on relighting the pilot light. Always follow the manufacturer’s specific guidelines to ensure safety and proper functioning, as procedures can vary between models and brands.
Relighting a Rheem Water Heater
To relight a Rheem water heater, start by rotating the gas knob clockwise to the “off” position and waiting five minutes. Then, rotate the knob counter-clockwise to the “Pilot Light” position and press down on the red button while activating the piezo ignitor striker until the pilot light ignites. Hold the red button for one minute to ensure the thermocouple heats sufficiently.
Relighting an A.O. Smith Water Heater
For A.O. Smith water heaters, remove the access panel, set the gas control to “Pilot,” and hold down the red button while pressing the ignitor button. Maintain pressure on the red button for about 60 seconds after ignition to ensure the pilot stays lit.
Relighting a Bradford White Water Heater
Bradford White water heaters require turning the control switch to pilot mode, pressing and holding the red control button while pressing the ignition button until you hear a click and see the status light blinking. Ensure you’re in a well-ventilated area and can clearly see the pilot assembly.
After relighting your water heater’s pilot light, verify proper operation by checking that the main burner ignites when the temperature is increased and that hot water is being produced.
Common Reasons Your Pilot Light Keeps Going Out

Common pilot light issues include gas pressure, dirty parts, or faulty thermocouples.
A pilot light that repeatedly extinguishes can be frustrating, but understanding the reasons behind it can help you find a long-term solution. If your water heater’s pilot light keeps going out, it’s essential to identify the underlying cause rather than simply relighting it over and over again.
Gas Pressure Issues
Gas pressure fluctuations can significantly affect your pilot light’s stability. Inconsistent gas pressure from your utility provider or issues with your home’s gas line can cause the pilot flame to extinguish unexpectedly, leading to a malfunctioning water heater.
Thermocouple Problems
A faulty thermocouple is one of the most common culprits behind a pilot light that won’t stay lit. This safety device senses when the pilot is lit and allows gas to flow. When it wears out or becomes covered in carbon deposits, it may falsely detect that the pilot is out and shut off the gas supply.
Drafts and Ventilation Issues
Drafts and ventilation issues around your water heater can easily blow out the small pilot flame. Check for nearby windows, doors, or return air vents that might create air currents strong enough to extinguish the pilot light, ensuring proper ventilation for your water heater.
Dirty Components or Blockages
Dirty components or blockages in the pilot tube, orifice, or air intake can restrict proper gas flow or create an improper air-gas mixture. This can result in a weak flame that’s prone to going out. Regular cleaning and maintenance can help prevent such issues with your pilot light.
Control Valve Failure
The gas control valve regulates gas flow to both the pilot and main burner. When it malfunctions, it can cause intermittent pilot light issues or complete failure. In such cases, professional replacement may be necessary to restore your water heater to proper functioning.
By understanding these common issues, you can take steps to prevent your pilot light from going out repeatedly. Regular maintenance of your water heater, including cleaning the pilot assembly and inspecting gas connections, can help extend the life of your system and prevent frustrating outages.
When to Call Valley Plumbing NW for Professional Help

Call Valley Plumbing NW when DIY fixes don’t solve the issue or if you smell gas.
While relighting your water heater’s pilot light can often resolve the issue, some situations require expert intervention. If you’ve made multiple attempts to relight your pilot light without success, it may indicate underlying problems with your water heater that need professional diagnosis.
Our team at Valley Plumbing NW is here to help with all your water heater needs, from installation and repairs to maintenance. We serve homeowners across Yamhill, Washington, Multnomah, and Marion counties, including cities like Newberg, Salem, Portland, Sherwood, and McMinnville.
Don’t let pilot light issues disrupt your hot water supply. Reach out to Valley Plumbing NW today at (503) 405-8391 or online. Our licensed technicians are experienced with all types of water heaters (electric, gas, and tankless) and can quickly diagnose and resolve complex issues.
Relighting Your Pilot Light Frequently Asked Questions
1. Why won’t my pilot light stay lit?
If your pilot light won’t stay lit, it could be due to a faulty thermocouple, improper gas pressure, or drafts affecting the flame. Troubleshooting these common causes can help you fix the issue and get your pilot light burning reliably again. Make sure to check for any loose connections or dirt around the pilot assembly, as these can also prevent the pilot from staying lit.
2. What should I do if I smell gas when trying to light the pilot?
If you smell gas, immediately turn off the gas supply and ventilate the area. Do not attempt to light the pilot, and contact a professional or your gas company to ensure your safety before proceeding further. It’s crucial to avoid using any electrical appliances or creating sparks in the area until the gas has been fully cleared.
3. How long should I wait before trying to relight the pilot light after turning off the gas?
Wait at least 5-10 minutes after turning off the gas supply to clear any residual gas. This precaution reduces the risk of explosion and ensures a safer relighting process. This waiting period also helps prevent the buildup of gas fumes that could ignite when trying to relight the pilot.
4. Can I relight the pilot light on any type of water heater?
Most gas water heaters have a pilot light, but the process to relight it can vary. Always refer to your water heater’s manual for specific instructions, as different models may require unique steps. Some modern water heaters may have automatic ignition systems, which could simplify the relighting process or eliminate the need for a pilot light altogether.
5. Why is my hot water not getting hot enough even after relighting the pilot?
If your water isn’t getting hot enough, check for issues like a malfunctioning thermostat, dirty burner, or incorrect temperature setting. Inspect these components and ensure the burner is clean for optimal heating performance. In some cases, the thermocouple may need replacement if it’s not detecting the flame properly, causing the burner to shut off prematurely.